| SALES | PHONE / WHATSAPP | |
|---|---|---|
| Jim Pei | [email protected] | +86 18020776782 |
| Model Number | 6ES7650-8PC00-0AA0 |
| Product Family | SIMATIC ET 200PA SMART |
| Product Type | Active backplane bus module |
| Module Format | Bus module 2 x 40 |
| Electronic Module Positions | 2 |
| Supported Module Width | 40 mm |
| Runtime Module Replacement | Supported in approved arrangement |
| Mounting | ET 200PA SMART mounting rail |
| Maximum Station Modules | 12 to the right of IM650 |
| High-Accuracy Timestamp Limit | 8 input modules |
| Backplane Bus Cover | Required for unused slots |
| Bus Module Cover | Required at final bus module |
| Hazardous-Area Arrangement | Use Ex partition where required |
| PURCHASING TERM | DETAILS |
|---|---|
| Minimum Order Quantity | 1 Piece |
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3–7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
|
01
Lock onto the mounting railThe active bus module installs on the designated ET 200PA SMART rail.
|
02
Carry the station backplaneAdjacent active bus modules form the backplane path.
|
|
03
Accept two electronic modulesTwo 40 mm module positions are provided.
|
04
Enable maintained operationApproved arrangements support replacement while the station remains running.
|
|
2 x 40
Module format
|
12
Maximum station modules |
8
Timestamped input modules |
| Two-position formatOne bus module accepts two 40 mm electronic modules. | Runtime service architectureActive backplane construction supports change during operation. | Station-order disciplineCovers, Ex partitions and the module-count limit must be observed. |
| 01 | How many electronic modules fit on 6ES7650-8PC00-0AA0? | It is the Bus Module 2 x 40 for two 40 mm electronic modules. |
| 02 | Why is 6ES7650-8PC00-0AA0 called an active bus module? | It forms the powered station backplane used for approved runtime replacement arrangements. |
| 03 | Where is 6ES7650-8PC00-0AA0 mounted? | Install it on the ET 200PA SMART mounting rail intended for active bus modules. |
| 04 | What closes unused positions around 6ES7650-8PC00-0AA0? | Use the required backplane-bus and end bus-module covers. |
| 05 | Which station limit affects systems using 6ES7650-8PC00-0AA0? | A maximum of 12 assemblies may be placed to the right of the IM650. |
| 06 | When is an Ex partition relevant near 6ES7650-8PC00-0AA0? | Use it when separating intrinsically safe and non-intrinsically safe station areas. |
| UDS1100002-01 | AV5155DN | DS7708-SR00004ZCWW |
| PLT200 | LU45BB | DM5240 |
| GX1230 | PH300 | CAN-5901 |
| DE1-121D4FN-N20N | DN33E9HR20 | XCSTE5311 |
| UNC-500 | IS-485NXL | AVP101 |
| CJS20W | GFG-8216A | VLC-1600Z-KC |
| VLC-12CH-10A | TPNN0077 | IAP-215-RW |
| FG-20i | AUH-01 | ATA4S-00 |
| EXP-1048 | MB3170 | NUM-ACT08 |
| CPO-RS6 | edmk-itf-c2 | MIL-RC3412-V2 |
| CCHE-CP12-6C-P003RH | OK34A | TCSESM043F23F0 |
| ECM-14001GB | LJ-G5001 | ADCDW2506TU |
| Q.PS-AD2-2402F | XG-E700 | XD508 |