Petite Quotationem Gratis

Noster legatus te cito adibit.
Electronicum
Nomen
Telephōnum mōbile
Nōmen societātis
Notula
0/1000

YOKOGAWA

Pagina Prima >  Producta >  YOKOGAWA

YOKOGAWA Bus Interface Module Supplier EB501-50 S2 Ready For Ship

Nomen producti: Bus Interface Module Supplier

Nomen marcae: YOKOGAWA

Numerus exemplaris: EB501-50 S2

Terra Originis: Iaponia

Warranty: 12 menses

Whatsapp:+86 18159889985

Epistula electronica: [email protected]

Appurtenance:
  • Conspectus
  • Contactus pro citatione
  • Specificationes
  • Descriptio
  • Aliquam commodo
  • Eigenschaften
  • THEORIA OPERATIONIS
  • FAQ
  • Producta Commendata

Conspectus

Nomen marcae:

YOKOGAWA

Numerus exemplaris:

EB501-50 S2

Terra Originis:

Iaponia

Particularia impaquetandi:

Originales nova Officina Sigillata

Tempus solutionis:

Tempus expeditionis, si in deposito

Conditiones solutionis:

T/T

Contactus pro citatione

Praepositus Venalium:

Stella

Mitte epistulam electronicam:

[email protected]

Contactus per Whatsapp:

+86 18159889985

Specificationes

Parameter

Specificatio

Formam

EB501-50 S2

Fabricator

Yokogawa Electric Corporation

Product Type

ER Bus Interface Slave Module

Architectura Bus

Yokogawa ER Bus (Ethernet Ring)

Velocitas communicationis

10 Mbps

Topologia rete

Architectura ring cum automatico fall-over

Supportus Redundantiae

Configuratio ER bus duplicata redundantia suportata

Typus coniunctionis

Bnc coniunctorem

Cable de transmissione

Cable coaxial (YCB141 aut YCB311)

Distantia maxima de transmissione

185 metros (cum cable YCB141)

Fontem electricitatis

24 VDC ab planum dorsale del systema

Consumptio currentis

0,7 A

Montatio

Installation standard del rack Yokogawa FIO I/O

Nodi unitates adfirmatae

ANR10S (singula), ANR10D (duplicata redundantia)

Temperatura operativa

0°C ad 55°C

Temperatura recondita

–20°C ad 70°C

Condicio initiationis frigidae

Usque ad 10 minuta praecalorisatio cum alimentatur ex deposito inter –20°C et 0°C

Pondus

Circa 0,3 kg

Dimensiones

144.65 × 130 × 32.8 mm (formatum cardinis FIO standard)

Certificationes

Certificatum secundum IEC 61508 SIL 3 pro applicationibus tutelae

Sisteme Compatibile

CENTUM VP, CENTUM CS 3000, ProSafe-RS

Suffixus Codex (-50)

Typus standard sine protectione contra explosionem

Descriptio

The EB501-50 S2 est modulus servus interfaciei ER Bus ab Yokogawa, ingenio constructus ut communicationem altam velocitatem inter Unitates Controlis Campi (FCUs) et nodos I/O remoti in systematibus controlis distributis CENTUM VP, CENTUM CS 3000, et ProSafe-RS constituat . The EB501-50 S2 operat in 10 Mbps super bus ER proprius Yokogawa, permittend exchange dati deterministici inter modulos FIO I/O et magister bus ER lateris controller . Supportans configurationes duplicis redundantis et certificatio salutis SIL 3, EB501-50 S2 praebet fiduciam gradus industrialis pro automatione processuum criticorum et systematibus instrumentorum salutis . Suffix "-50" indicat typum standard sine protectione contra explosiones .

Aliquam commodo

  • Certificatio de incolumitate SIL 3 – Certificatus pro usu in systematibus instrumentorum salutis (SIS) secundum IEC 61508 et IEC 61511, idoneus ergo pro systematibus arrestus emergentis (ESD), detectione ignis et gas, et applicationibus gestionis combustorii .

  • Architectura anuli tolerantis defectus – Cum deploytur in configurationibus redundantibus bus ER, modulus automatico detegit defectus rete et redirecit communicationem intra 10 milliseconda, servans operationem continuam durante interruptionibus cableorum aut defectibus interruptorum .

  • Communicatio altius velocitatis et deterministica – Offers sub-millisecond response times for time-critical control loops, ensuring precise synchronization between distributed field devices and central controllers .

  • Dual-Redundant Bus Support – Supports redundant transmission paths on the ER bus for enhanced system availability .

  • Seamless CENTUM Integration – Plug-and-play auto-configuration capabilities eliminate manual network setup—the module automatically discovers its position in the ER bus topology and establishes communication with the system controller upon power-up .

  • Hybrid DCS-SIS Architectures – Enables integrated control and safety systems where basic process control and safety-critical functions coexist on shared infrastructure while maintaining functional separation required by safety standards .

Eigenschaften

  • ER Bus Slave Communication – Provides direct physical and electrical execution of communication between FIO I/O modules and the ER Bus master architecture

  • 10 Mbps Transmission Speed – Facilitat exchangementem rapidum et efficacem signorum controlis et datarum processus inter contrōllātōrem et apparātūs campī

  • Coniunctiō BNC Coaxiālis – Utitur cābō coāxiālī (YCB141 aut YCB311) terminātō cum connēxīvīs BNC ad connēxionem strūctūralem rōbustam

  • Operātiō Dualis Redundāns – Suadet configūrātiōnēs redūndāntēs ER bus ad altam fidēlitātem systēmātis

  • Sīcūritās Functionālis SIL 3 – Certificātum est pro systēmātibus instrumentōrum sīcūrōrum quae ad normās IEC 61508 et IEC 61511 cōnformantur

  • Plug-and-Play Auto-Configūrātiō – Discōveria automātica et constitūtiō communicātiōnis cum contrōllātōre systēmātis post initium potestātis

  • Diagnostics LED Comprehensiva – Indicātōrēs status in tempore reāle pro potestāte, activitāte communicātiōnis et conditiōnibus defectūs

  • Operatio in Latis Temperaturis – Operat ex 0°C ad 55°C, cum facultate incipientis frigidae usque ad –20°C

  • G3 Supportatio Ambientalis – Protectio contra gas corrosivos, ubi utitur cum variantibus nodi idoneis

  • Continua Diagnostica Automatica Apparatus – Monitoratio continua status valetudinis et notitiae de statu communicationis

THEORIA OPERATIONIS

The EB501-50 S2 functionat ut interfacies communicationis servilis intra architecturam bus ER (Ethernet Ring) Yokogawa, connectens Unitates Controlis Campi (FCUs) ad nodos I/O remotos quae continent varios modulos I/O .

Communicatio Bus. Modulus operatur in topologia anuli, accipiens et transferens pacheta data inter magistrum bus ER (typice situm in FCU) et dispositiva campi connexa per Unitates Nodorum Bus ER (ANR10S aut ANR10D) . Translatio data fit ad 10 Mbps super cavo coaxiali (YCB141 aut YCB311) cum connectoribus BNC .

Redundantia & Tolerantia Errorum. In dual-redundant configurations, the module supports automatic failover with sub-10 ms recovery time . If a cable break or switch failure occurs on the primary path, communication is automatically rerouted through the secondary path without interrupting process control .

Auto-Discovery & Initialization. Upon power-up, the module automatically discovers its position in the ER bus topology and establishes communication with the system controller . In cold start conditions (powered from –20°C to 0°C storage), the module requires up to 10 minutes warm-up before full operation .

Data Exchange. The module manages the physical and electrical execution of communication between FIO I/O modules and the ER Bus master . It handles internal bus timing, arbitration, and data routing while maintaining separation between field-side signal processing and controller communications.

Safety Integration. Cum deployatur in configurationibus ProSafe-RS SIS, modulus connectit modulos I/O de securitate, qui variabiles processuales criticas (pressionem, temperaturam, altitudinem) observant, ad solutores logicos de securitate, qui actiones protectivas exeuntur dum condicionibus operativis anormalibus .

FAQ

Q1: Quae est functio principalis EB501-50 S2?

A1: Ille EB501-50 S2 fungitur ut Modulus Interficialis ER Bus Servus, qui Unitates Controlis Campi (FCUs) connectit ad nodos I/O remotos per proprium ER bus Yokogawa, permittens transmissionem datorum 10 Mbps inter modulos I/O FIO et magistrum ER Bus lateris controlleris .

Q2: Quid suffixa "-50" et "S2" significant?

A2: “-50”suffixum indicat typum standardem sine protectione contra explosiones . The "S2" suffixum denotat revisionem hardware specificam aut variantem configurationis.

Q3: Utrum EB501-50 S2 communicationem redundatem suportat?

A3: Ita. Licet modulus ipse saepius in configuratione singula utatur, rete ER bus, cui connectitur, configurari potest cum viis transmittendi redundantibus . Modulus suportat configurationes ER bus duplicatas pro fiducia systematis augmentata .

Q4: Quae genera cavi et connexorum utuntur cum EB501-50 S2?

A4: Modulus utitur cavo coaxiali—scilicet Yokogawa YCB141 aut YCB311—pro coniunctione physica ad rete ER bus, terminato conectore BNC . Maxima distantia transmissionis pro singulo segmento utente cavo YCB141 est 185 metra .

Q5: Quae systemata et unitates nodi compatibilia sunt cum EB501-50 S2?

A5: EB501-50 S2 compatibile est cum systematibus Yokogawa CENTUM VP, CENTUM CS 3000, et ProSafe-RS . Installari potest in unitatibus nodi ER Bus ANR10S (Simplex) et ANR10D (Duplex Redundans) .

Interroga nunc: [email protected]

Petite Quotationem Gratis

Noster legatus te cito adibit.
Electronicum
Nomen
Telephōnum mōbile
Nōmen societātis
Notula
0/1000

Petite Quotationem Gratis

Noster legatus te cito adibit.
Electronicum
Nomen
Telephōnum mōbile
Nōmen societātis
Notula
0/1000